About Slim Collection

Rectifiers for AC voltage and PWM modules for DC voltage

Thanks to extremely compact design the overexcitation rectifier "Slim Collection" can be installed in very restricted space. The module features a central bore for screw fixing inside the terminal box. It can also be installed by using an adhesive pad.

 

Features at a glance

  • Cost-effective
  • Very small design (LxBxH): 60x24x19 mm
  • Versatile options for assembly and connection
  • Integrated fast shutdown
  • Energy savings up to 75%

Versions

  • Slim Collection AC - overexcition
    These types of Slim Collection AC operate as a time controlled rectifier with integrated electronic fast turn-off through voltage detection.

  • Slim Collection AC - half-wave/bridge
    These types of Slim Collection AC operate as a half-wave/bridge rectifier with integrated electronic fast turn-off through voltage detection (depending on type).

  • Slim Collection DC - DC voltage
    The Slim Collection DC operates as a time-controlled PWM amplifier (pulse width modulation).

Technical Details

Type Slim Collection AC - overexcition Slim Collection AC - half-wave/bridge Type Slim Collection DC - with DC voltage
Rectification Time-controlled bridge / one-way switching Bridge / half-wave rectifier Principle of operation Controlled pulse width modulation (PWM)
Rated input voltage 100 VAC to 240 VAC / 220 VAC to 500 VAC 0 VAC to 500 VAC Basic frequency PWM 20 KHz
Output voltage Uin * 0,98 / Uin * 0,445 Uin * 0,98 or Uin * 0,445 Overexcitation time 0,2 s
Output current Overexcitation 2,0 A / Stop 1,0 A max. 0,8 A (depending on type) Input voltage 24 VDC to 48 VDC
Quick shutdown yes (via internal voltage detection) yes (depending on type) Output voltage 50% / 70% / other settings from customer request possible
Connections Clamp and wire Clamp and wire Output current max. 2,0 A
Nominal excitation time 0,2s   Connections Clamp and wire

Downloads

Need more information?

Datasheet | Slim Collection | 32 x7101B5x
pdf - 320 KB
Datasheet | Energy saving module | 34 10125Xxx
pdf - 239 KB
Video Electronic modules

Kendrion Tutorial - Electronic modules for electromagnetic brakes

Electromagnetic brakes can be optimized by using electronic control modules. These can improve the technical properties and reduce heat and energy consumption.
AdobeStock_221826107.jpeg
image overlay
Kendrion Industrial Brakes
Sales Team Kendrion Villingen